Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiation Oncology ; (6): 260-265, 2022.
Article in Chinese | WPRIM | ID: wpr-932664

ABSTRACT

Objective:To introduce the stereotactic cardiac radioablation (SCRA) based on the stereotactic body radiotherapy (SBRT), and comprehensively evaluate the new approach by short-term effectiveness and safety.Methods:Patients with ventricular arrhythmia (VA) were evaluated and included in this clinical trial, who were immobilized by vacuum bag and performed simulation with 4-dimensional computed tomography (4DCT). In this study, the planning target volume (PTV) was set as the target to design a SBRT plan using volumetric modulated arc therapy (VMAT), which was evaluated by dose parameters such as R 50%, homogeneity index and conformity index, etc. The results of Holter and echocardiography were monitored during the follow-up and compared with the data before treatment. Results:Three subjects with ventricular tachycardia (VT) and one with premature ventricular contraction (PVC) received the same prescription of 25 Gy in a single fraction. The average volume of PTV was 71.4 cm 3(60.3-89.4 cm 3). The average time of beam delivery was 12.0 min (4.5-21.0 min). And the short-term follow-up lasted for an average of 18 weeks (14-25 weeks), which showed significant decrease in both VT and PVC load without complications. Conclusion:This study reports the implementation method of SCRA and proves its short-term effectiveness and safety, but the effects and standards of the key radiotherapy techniques still need to be explored.

2.
Chinese Journal of Radiation Oncology ; (6): 592-597, 2021.
Article in Chinese | WPRIM | ID: wpr-910433

ABSTRACT

Objective:To retrospectively analyze the setup errors of thermoplastic head and shoulder molds alone or combined with vacuum pad in hypofractionated stereotactic radiotherapy (HFSRT) for non-small cell lung cancer (NSCLC) with brain metastases.Methods:Fifty-four NSCLC patients with brain metastases who received HFSRT from 2017 to 2019 were enrolled in this study. Twenty-four patients were fixed with thermoplastic head and shoulder molds (group A), and 30 patients were fixed with thermoplastic head and shoulder molds plus vacuum pad (group B). The interfraction and intrafraction setup errors were acquired from cone-beam CT online image registration before and after the HFSRT. Optical surface system was applied in monitoring the intrafraction setup errors. The setup errors in each direction between two groups were analyzed by independent samples t-test. Results:For the interfraction setup errors of the whole group, the proportion of the horizontal setup errors of ≥3mm was 7.0% to 15.4% and 7.0% to 12.6% for the rotation setup errors of ≥2°. In group A, the anteroposterior setup error was (1.035±1.180)mm, significantly less than (1.512±0.955)mm in group B ( P=0.009). In group A, the sagittal rotation setup error was 0.665°±0.582°, significantly less than 0.921°±0.682° in group B ( P=0.021). For the intrafraction setup errors of the whole group, the proportion of horizontal setup errors of ≥1mm was 0% to 0.7%, whereas no rotation setup error of ≥1° were observed. In group B, bilateral, anteroposterior and sagittal rotation setup errors were (0.047±0.212)mm, (0.023±0.152)mm and 0.091°±0.090°, significantly less compared with (0.246±0.474)mm, (0.140±0.350)mm and 0.181°±0.210° in group A ( P=0.004, P=0.020, P=0.001), respectively. Optical surface monitoring data were consistent with the obtained results. Conclusions:Thermoplastic head and shoulder molds (with or without vacuum pad) combined with online image registration and six-dimensional robotic couch correction can be applied in HFSRT for brain metastases from NSCLC. The intrafraction setup errors in group B are smaller than those in group A. Optical surface system has certain value in monitoring the intrafractional movement.

3.
Journal of Biomedical Engineering ; (6): 1288-1293, 2015.
Article in Chinese | WPRIM | ID: wpr-357878

ABSTRACT

Intensity-modulated radiotherapy planning for nasopharyngeal carcinoma is very complex. The quality of plan is often closely linked to the experience of the treatment planner. In this study, 10 nasopharyngeal carcinoma patients at different stages were enrolled. Based on the scripting of Pinnacle 9. 2 treatment planning system, the computer program was used to set the basic parameters and objective parameters of the plans. At last, the nasopharyngeal carcinoma intensity-modulated radiotherapy plans were completed automatically. Then, the automatical and manual intensity-modulated radiotherapy plans were statistically compared and clinically evaluated. The results showed that there were no significant differences between those two kinds of plans with respect to the dosimetry parameters of most targets and organs at risk. The automatical nasopharyngeal carcinoma intensity-modulated radiotherapy plans can meet the requirements of clinical radiotherapy, significantly reduce planning time, and avoid the influence of human factors such as lack of experience to the quality of plan.


Subject(s)
Humans , Carcinoma , Feasibility Studies , Nasopharyngeal Neoplasms , Radiotherapy , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated
SELECTION OF CITATIONS
SEARCH DETAIL